  • ProMaxion Mass Spectrometer Proven Effective in Determining Flare Gas Heat Values

ProMaxion Mass Spectrometer Proven Effective in Determining Flare Gas Heat Values

Report this content

Contact: Anthony Slapikas, (412) 826-2452, tony.slapikas@ametek.com

PITTSBURGH, PA— By January 2019, petroleum refiners will need to comply with new US Environmental Protection Agency flare stack combustion rules that include additional monitoring and analysis requirements making it necessary for operators to quickly and accurately determine the heat values of flare stack gases.

Refiners are vetting various technologies for analyzing and monitoring flare stack gases to narrow the field of applicable and reliable technologies ahead of that deadline. Among them is mass spectrometry as utilized by the ProMaxion quadrupole process mass spectrometer from AMETEK Process Instruments.

The capabilities of the ProMaxion versus competitive technologies already were field demonstrated by a leading Southern California refinery that needed to meet similar regulations that were promulgated by the California Air Quality Management Board. That field experience demonstrated that the ProMaxion offered more detailed and relevant data faster than gas chromatography and that it provided BTU numbers that were the equivalent of those provided by a calorimeter, but with greater specificity.

The ProMaxion had the speed and specificity necessary to calculate the appropriate amount of make-up gas for complete combustion. The ProMaxion was set up to monitor and quantify 16 components in the flare gas stream, including H2, N2, methane, ethane, propane, n-butane, i-butane and pentanes among others.

Taking advantage of its analysis speed, the ProMaxion was able to obtain an accurate calculation in less than 10 seconds, which was more than 10 times faster than using a chromatograph.

By modifying the standard process mass spectrometry method of analysis slightly, the ProMaxion provided fast and accurate BTU content measurement even when confronted with a widely changing flare gas stream. The analysis technique allowed for a reduction in calibration complexity, while still providing data that fell comfortably within the specified error band.

The ProMaxion used ASTM method D 2650-04 (Standard Test Method for Chemical Composition of Gases by Mass Spectrometry) to calculate the concentrations of individual gas components.  The resulting data was then converted into the flare gas heat value as described in ASTM D3588-98 (Standard Practice for Calculating Heat Value, Compressibility Factor and Relative Density of Gaseous Fuels).

Proprietary software provides for easy set-up, operation and calibration, combined with advanced alarm and automation capabilities. The ProMaxion’s modular design and self-diagnostic capabilities ensure ease of maintenance. The instrument is housed in a stainless steel enclosure (general purpose or C1, D2 area classification).

About AMETEK Process Instruments

AMETEK Process Instruments is a unit of AMETEK, Inc., a leading global manufacturer of electronic instruments and electromechanical devices. It offers the industry’s most extensive line of process instruments with analyzers based upon eleven differentiated technology platforms for markets ranging from oil and gas, and power to pharmaceutical and semiconductor manufacturing.

The ProMaxion additionally draws on AMETEK’s more than 25 years of experience in mass spectrometer design and manufacture as well as nearly 40 years of experience in the design and development of sophisticated process analyzers.

For more information, contact AMETEK Process Instruments, 150 Freeport Road, Pittsburgh, PA 15238.   Phone: (412) 828-9040. Fax: (412) 826-0399.  Web site: www.ametekpi.com

Tags:

Media

Media

Quick facts

Petroleum refiners will need by 2019 to comply with new flare stack combustion rules
Tweet this
ProMaxion process mass spectrometer has proven capabilities for analyzing, monitoring flare stack gases
Tweet this
Capabilities field-proven by Southern California refinery
Tweet this